摘要
对GB 50116-2013《火灾自动报警系统设计规范》和GB 50016-2014《建筑设计防火规范》中关于电气火灾监控、安防系统联动控制、消防控制室、应急照明和疏散指示标志、消防配电线路敷设的相关条文进行了分析与探讨,希望对规范今后修订、健全和完善以及规范的正确、合理执行提供有益帮助。
The author analyzes and discussion about the electric fire prevention、automatic control of security system,fire control center,fire emergency lighting and signage evacuation,line laying of fire power of GB50116-2013 and GB50016-2014. All of these amendments seeks to improve,perfect and correctly,reasonably executed of the codes to provide useful help.
出处
《广东土木与建筑》
2015年第2期42-44,共3页
Guangdong Architecture Civil Engineering
关键词
火灾自动报警系统
安防系统联动控制
应急照明
消防配电线路敷设
automatic fire alarm system
automatic control of security system
fire emergency lighting
line laying of fire power