摘要 指出选择合理的给水方式是高层建筑消防给水系统设计的关键。提出建筑高度是确定高层建筑消防给水系统系统竖向分区的主要因素。当建筑高度小于70m左右时,采用不分区的给水方式;当建筑高度大于70m左右时,应采用分区给水方式。应结合工程实际情况选择经济合理的给水方式。 Selection of rational pattern for water supply is a key point in design of water supply system for fire protection in high-rise buildings. It is pointed out that the building height is the main factor for vertical zoning of water supply system for fire protection in high-rise buildings. When the building height is less than 70M, no zoning is applied for water supply system and when the height is more than 70M, water supply with zoning should be applied. The selection of rational water supply pattern should be based on practical condition of the project.
作者 魏福森
出处 《重庆建筑大学学报》 CSCD 2002年第5期76-79,共4页 Journal of Chongqing Jianzhu University
关键词 高层建筑 消防给水 竖向分区 选择 high-rise building water supply for fire protection vertical zoning selection