机械驱动水—水热泵系统的实验研究

Experimental research of mechanically driven water-to-water heat pump systems
下载PDF
导出
摘要 研制了机械驱动水—水热泵实验装置。实验研究揭示 :转速变化会导致系统性能变化 ;系统的EER特性在转速变化范围内有极值 ,所以系统的额定工况可选定在该转速下 ;系统的制热量变化幅度大 ,能在额定工况上下调节 ;采用混合换热器回收发动机余热和尾气废热 ,能使局部流量范围的出水温度达到 95℃。对燃用天然气的内燃机驱动水—水热泵系统与电动热泵系统的能源消耗作经济比较 ,得出了可用于判断其应用前景的能源消耗准则。 Developed a water-to-water heat pump system driven by an internal combustion engine. Used a mix heat exchanger to recover heat from the engine. Based on experimental results, the studied system characteristics has a maximum value of EER in the range of rotational speed of compressor and water temperature of the heat pump system at a certain flow rate can reach 95 ℃. Compares the electric heat pump with the gas driven heat pump and obtains an energy consumption relationship which can be used for evaluating the applicability of the gas driven heat pump system.
机构地区 天津大学
出处 《暖通空调》 北大核心 2002年第6期20-23,共4页 Heating Ventilating & Air Conditioning
基金 天津市科技发展项目资助 (编号 30 10 14 )
关键词 机械驱动热泵 天然气 能效比 混合换热器 空调系统 mechanically driven heat pump, natural gas, energy efficiency ratio, coefficient of performance, mixed heat exchanger, energy consumption relationship
  • 相关文献

参考文献2

  • 1Cube Von HL Steimle F.热泵的理论与实践[M].北京:中国建筑工业出版社,1986..
  • 2吕灿仁.热力学、环境、能源与可持续发展.面向21世纪热科学论文集[M].北京:高等教育出版社,1999..