期刊文献+

杭州萧山国际机场航站楼空调通风设计 被引量:5

Air conditioning and ventilation system design for the terminal building of Hangzhou Xiaoshan International Airport
下载PDF
导出
摘要 介绍了航站楼空调、通风和排烟设计。结合该工程大空间的特点 ,采用地面送风亭射流送风 ,沿玻璃幕墙地面设长条形地面送风口 ,既可满足人的舒适要求 ,又可防止玻璃幕墙结露 ;候机大厅和办票大厅顶部设红外线对射探测器控制的排烟天窗。航站楼已正常运行 2年。 Presents the design of air conditioning, ventilating and smoke exhaust system of the terminal building. Owing to large space of the building, adopts prismatic air supply columns floor slit air outlets along the glass curtain wall. It not only meets the comfort requirements of passengers but also prevents glass curtain wall from condensing. Some smoke exhaust windows controlled by infrared detectors are installed on the roofs of the waiting hall and check-in hall. The project has operated normally for two years.
出处 《暖通空调》 北大核心 2002年第6期75-77,共3页 Heating Ventilating & Air Conditioning
关键词 杭州萧山国际机场 航站楼 空调 通风 设计 排烟 air terminal building, air supply mode, ventilation, smoke exhaust design
  • 相关文献

参考文献1

  • 1第四机械工程部第十设计研究院.空气调节设计手册(第2版)[M].北京:中国建筑工业出版社,1995..

同被引文献21

引证文献5

二级引证文献8