摘要
总结了国家电力调度中心低温送风空调系统施工安装经验 ,介绍了减少风管系统漏风量的措施、风管保温新工艺、末端装置及低温风口等的安装 ,认为减少风道漏风量和做好风水系统保温是低温送风空调系统安装质量控制的两个要点。
Sums up construction and installation experience of low temperature air supply system of State Power Control Center. Presents measures to reduce duct leakage rate, new insulation technique for duct and installation of terminal air supply devices and low temperature air supply outlets. Considers that reducing air leakage and heat prevention of pipe and duct are two key points to quality control of installation of low temperature air supply system.
出处
《暖通空调》
北大核心
2002年第6期115-117,共3页
Heating Ventilating & Air Conditioning
关键词
国家电力调度中心
低温送风
空调系统
施工
安装
low temperature air supply, air conditioning system, construction and installation