摘要 依据JJF1059-2012《测量不确定度评定与表示》技术规范,科学合理地评定测量不确定度,分析了数字压力计示值基本误差检定中不确定度来源主要分为测量重复性、计量标准器及箱体的控制稳定性等3个方面,选取被检表在高点1 050hPa、中间点970hPa、低点890hPa进行多次重复测量,从而计算出在每个被测点的合成不确定度和扩展不确定度,分析数字压力计测量结果不确定度评定方法,对保证数字压力计的量值传递可靠具有重要意义,并对今后数字气压计测量结果不确定度分析提供了参考价值。 According to JJF1059-2012'Evaluation and Expression of Measurement Uncertainty',this paper analyzes the sources of uncertainty in the calibration of basic errors of digital pressure gauges,which are mainly divided into three aspects:measurement repeatability,control stability of measuring standard and box,and selects the high point 1 050 hPa,middle point 970 hPa,and so on.The low point 890 hPa is measured repeatedly,and the combined uncertainty and extended uncertainty at each measured point are calculated.The reliability of digital pressure gauge verification is guaranteed.
作者 刘宇 刘文忠 武春爱 Liu Yu;Liu Wenzhong;Wu Chun’ai(Meteorological Technology and Equipment Center in Hebei Province,Shijiazhuang 050021,China)
出处 《国外电子测量技术》 2019年第8期134-136,共3页 Foreign Electronic Measurement Technology
关键词 数字压力计 测量 不确定度 digital pressure gauge measurement uncertainty
  • 相关文献

参考文献13

二级参考文献34

  • 1孙继刚.计算机串口通讯技术与单片机[J].重工与起重技术,2004(2):18-19. 被引量:3
  • 2李建英,贺晓雷.振筒气压仪性能测试[J].气象科技,2004,32(4):291-293. 被引量:3
  • 3JJG875-2005,数字压力计检定规程[S].
  • 4压力测量不确定度评定.中国计量测试学会压力专业委员会组编.中国计量出版社出版.
  • 5JJG875—2005数字压力计检定规程.
  • 6JJG272—2007空盒气压表和空盒气压计检定规程.
  • 7JJF1059-1999(测量不确定度评定与表述》.
  • 8JJG860-1994(压力传感器(静态)检定规程》.
  • 9JJFl059-1999.测量不确定度评定与表示.[S].,..
  • 10JJF1059-1999.测量不确定度评定与表示[S].[S].,1999..

共引文献53

同被引文献66

引证文献6

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部