摘要
为了保证电压互感器的准确度和可靠性,需要对其进行准确度校验。传统校验方式定期进行,需要线路停电,周期较长,无法及时发现互感器存在的问题。针对这种情况,文中提出了一种基于开合式电容传感方法的电压互感器误差带电校验系统,利用采用两个开合式电容器及其他辅助器件构成的电压传感器作为标准传感器,利用两开合式电容器输出相互比对的形式实现传感器准确度自检,并利用其输出的平均值作为最终输出,大大提高了校验准确度及可靠性。测试结果证明该带电校验系统在额定电压的20%~120%范围内,比差变化小于0.037%,角差变化小于0.45′。
To ensure the accuracy and reliability of a voltage transformer,it is necessary to calibrate its accuracy.However,the traditional calibration method needs to be carried out periodically in the condition of outage,and some-times it cannot find transformer’s fault due to longer calibration time. In view of the fact,this paper proposes a volt-age transformer error online calibration system based on the open-closed capacitor sensing method. In this method,two open-closed capacitors and other auxiliary devices are used to compose a voltage sensor,and it is taken as the standard sensor. The outputs of the two open-closed capacitors are compared with each other to achieve self-test of sensor accuracy,and the average value of the outputs is used as the final output. Hence,the accuracy and reliability of the calibration are greatly improved. Test results show that the present system works within 20%~120% of the rated voltage,the variation of the ratio error is less than 0.037%,and the variation of the phase error is less than 0.45′.
作者
张宏伟
宋燕
张鸿
李平林
朱辉堂
李振华
ZHANG Hongwei;SONG Yan;ZHANG Hong;LI Pinglin;ZHU Huitang;LI Zhenhua(Jinchang Electric Power Company,State Grid Gansu Electric Power Company,Gansu Jinchang 737100,China;Storage and Transportation Department of Hongxing Iron&Steel Co.,Ltd.,Jiuquan Iron and Steel(Group)Corporation,Gansu Jiayuguan 735100,China;College of Electrical Engineering&New Energy,China Three Gorges University,Hubei Yichang 443002,China)
出处
《高压电器》
CAS
CSCD
北大核心
2019年第3期208-213,共6页
High Voltage Apparatus
基金
国家自然科学基金自助项目(51507091)~~
关键词
电压互感器
带电校验
改进数字积分
开合式电容器
voltage transformer
online calibration
improved digital integrator
open-closed capacitor