期刊文献+

太湖流域市政污水处理厂一级A标准稳定运行存在问题探讨 被引量:4

Problems in the municipal sewage treatment plants of Taihu Basin in adopting level1A discharge standard
下载PDF
导出
摘要 为了适应水环境保护工程的新要求,我国许多污水处理厂都面临着需要提标改造到一级A标准的局面。本文对一级A标准的发展、研究重点以及存在的问题等方面进行了讨论,并对执行一级A标准的太湖流域污水处理厂如何稳定运行提出建议。本文还重点探讨了碳源不足、低温等因素对污水处理厂运行的影响,此外,对污水处理厂如何在提标改造中进行节能降耗也提出了建议。最后对今后污水处理厂提标改造进行了展望。 In order to adapt the new demand of the protection on water environment,many wastewater treatment plants were required to upgrade to reach the class1 A of discharge standard of pollutants for municipal wastewater treatment plant( GB18918-2002). In this paper,we proposed suggestions on the operation of WWTPs in Taihu basin in order to make them reach the discharge standard of class1 A in stable. Factors which affected the performance of WWTPs,such as lack of carbon source and low temperature were discussed. Furthermore,proposals were given on how to save energy and cost during the upgrading and reconstruction of WWTPs as well. Finally,enhancing the operation capability of WWTPs was prospected in the future.
出处 《环保科技》 2016年第5期46-50,共5页 Environmental Protection and Technology
基金 国家水体污染控制与治理科技重大专项(2013ZX07314-002-02)
关键词 一级A 提标改造 稳定运行 节能降耗 first A level standard upgrading and reconstruction poor carbon source energy saving and cost reducing
  • 相关文献

参考文献17

二级参考文献73

共引文献267

同被引文献27

引证文献4

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部