期刊文献+

虚拟数字滤波提高红外气体分析系统精度的应用研究 被引量:3

Research on Improving System Accuracy of Infrared Gas Analyzers Based on Virtual Digital Filters
下载PDF
导出
摘要  探讨影响红外气体分析系统精度的主要因素;提出将虚拟仪器软件平台LabWindows/CVI应用于该系统,介绍CVI的典型滤波函数,在此基础上设计数字滤波器,编写相应程序;用基于PC机的数据采集卡及数字滤波器对本系统检测信号进行处理;简化系统硬件设计,缩短开发周期,与传统处理相比可有效消除各种干扰,改善系统的性能。 Key factors affecting system accuracy of infrared gas analyzers were discussed in this paper.The idea of applying virtual instrument software platformLabWindows/CVI to this system was presented.Typical filter function of CVI was introduced.Based on this,a digital filter was designed and relevant programs were compiled.Measuring signal of the system was processed using the digital filter and data acquisition block based on PC.The design of system hardware is simplified and developing cycle can be shortened.Many kinds of interferences have been effectively eliminated compared with traditional processing and the performance of system has been improved.
出处 《化工自动化及仪表》 CAS 北大核心 2002年第6期61-63,共3页 Control and Instruments in Chemical Industry
基金 国家自然科学基金项目资助(50077016)
关键词 虚拟数字滤波 精度 红外气体分析器 LABWINDOWS/CVI 虚拟滤波器 信号处理 infrared gas analyzer LabWindows/CVI virtual digital filter signal processing
  • 相关文献

参考文献3

  • 1靳斌,罗罡,杨冠玲,何振江.8098单片机在GXH-102红外气体分析器中的应用[J].重庆大学学报(自然科学版),1997,20(6):36-42. 被引量:1
  • 2Fairley,P D,Rutt,H N.A Novel Gas Concentration Monitor Using a Solid-state Modulator[J].Sensors and Actuators,2001,75:192-196.
  • 3LabWindows/CVI Standard Libraries Reference Manual[M].National Instruments Corp,1998.

二级参考文献4

  • 1周昌震,红外气体分析仪,1991年,102页
  • 2陈捷光,光学式分析仪器,1990年,211页
  • 3费业泰,误差理论与数据处理,1987年,76页
  • 4希尔 D W,不分光红外线气体分析,1975年,95页

同被引文献16

  • 1林继鹏,刘君华,凌振宝.并行支持向量机算法及其应用[J].吉林大学学报(信息科学版),2004,22(5):453-457. 被引量:7
  • 2林继鹏,刘君华.基于支持向量机的多组分气体分析[J].西安交通大学学报,2005,39(6):586-589. 被引量:6
  • 3林继鹏,刘君华.基于小波基的SVM多气体融合[J].吉林大学学报(信息科学版),2005,23(4):402-407. 被引量:5
  • 4张广军,吕俊芳,周秀银,袁梅.红外气体分析中环境影响的补偿方法研究[J].北京航空航天大学学报,1996,22(6):655-659. 被引量:12
  • 5张永怀 林继鹏 刘君华.基于RBF神经网络与光学气敏阵列技术的红外气体分析仪研究[J].仪器仪表学报,2004,26(4):45-49.
  • 6HARA H,KISHI N,IWAOKA H.Silicon Bolometer and Micro Variable Infrared Filter for CO2 Measurement,Optical MEMS[C]//2000 IEEE/LEOS International Conference.2000:139-140.
  • 7CHILDERS J W,THOMPSON Jr E L,HARRIS D B,et al.Multi-pollutant Concentration Measurements around a Concentrated Swine Production Facility Using Open-path FTIR Spectrometry[J].Atmospheric Envi-ronment,2001,(35):1923-1936.
  • 8BURGES C J C.A Tutorial on Support Vector Machines for Pattern Recognition[J].Data Mining and Knowledge Discovery,1998,36(2):121-167.
  • 9BURGES C J C.Simplifed Support Vector Decision Rules[C]//Lorenza Saitta,Pro-ceedings of the Fifteenth International Conference on Machine Learning.Bari,Italy,2004.
  • 10张广军,吕俊芳,周秀银,周浩敏.新型红外二氧化碳分析仪[J].仪器仪表学报,1997,18(2):134-138. 被引量:13