期刊文献+

血小板保存期间血小板计数和P-选择蛋白的变化 被引量:8

Change of Platelet Count and P-Selectin in Preserved Platelet Concentrates
下载PDF
导出
摘要 探讨CS 30 0 0plus血细胞分离机全密闭 5天保存袋保存的血小板数量和质量的变化 ,研究在 (2 2± 2 )℃条件下振荡和静置两种方法保存的血小板有无差异。采用SysmexF 82 0型全自动血细胞分析仪对机采血小板产品计数 ,应用酶联免疫吸附法 (ELISA)定量检测机采血小板上清液中P 选择蛋白的含量。结果显示 ,振荡与静置两种方法保存的血小板产品中血小板计数和P 选择蛋白含量均无显著性差异。随保存时间延长 ,振荡和静置保存的血小板计数逐渐减少和P 选择蛋白逐渐增多 ,其中两组内的血小板计数在保存 0 - 72小时以内均无显著性差异 ;而在保存 96 - 1 2 0小时后与保存前比较都有显著性差异。振荡保存组 0 - 72小时内 ,每相邻 1天之间P 选择蛋白量无显著性差异 ,其余各时间段均有显著性差异 ;静置保存组 0 - 72小时内各时间段均无显著性差异。结论 :①使用CS 30 0 0plus血细胞分离机全密闭 5天保存袋 ,对血小板制品的有效保存期以 3天为宜 ;②在 (2 2± 2 )℃条件下 ,振荡保存的血小板在数量和质量上并不优于静置保存的血小板。 To observe the change of quantity and quality of platelets preserved in a full sealed bag, and explore the difference of platelets preserved in oscillating and static conditions at (22±2)℃, the platelet concentrates were prepared with a CS 3000 plus blood cell separator, the platelet counts were performed with automatic blood cell analyzer and P selectin in supernatant of platelet concentrates was detected by ELISA. The results showed that both of platelet count and P seletin content in the platelet concentrates had no significant difference between oscillating and static preservation condition. With prolongation of preserved time, the platelet count decreased and P selectin content increased gradually in both preserved conditions. There was no difference in the platelet counts during 0-72 hours preservation in both conditions, and significant difference was seen in 96-120 hours preservation. It was concluded that the expired date for platelet product preserved in CS 3000 pluw blood cell separator full sealed system should be 3 days. Under the condition of (22±2)℃, the quality of the platelet preserved in oscillating state is not superior to static preservation.
出处 《中国实验血液学杂志》 CAS CSCD 2002年第6期571-573,共3页 Journal of Experimental Hematology
关键词 血小板保存 血小板计数 P-选择蛋白 platelet platelet preservation P selectin
  • 相关文献

参考文献5

二级参考文献9

  • 1Murphy S, Kahn RA, Holme S, et al. Improved storage of platelets for transfusion in a new container. Blood, 1982; 60:194 -200
  • 2Kretschmer V, Biermann E, Loh H. Separation of platelet concentrates (PC) from buffy coat (BC) using the bottom and top drainage (BAT) system. Beitr-Infusions ther, 1990; 26:65 - 70
  • 3George JN, Pickett EB. Platelet membrane glycoprotein changes during the preparation and storage of platelet concentrates. Transfusion, 1988; 28:123-126
  • 4Neumller J, Tohidast-Akrad M, Jilch R, et al. Standardization of the flow cytometric determination of HLA class 1 antigens ‘ plateletspecific' glycoproteins and activation marks. Vox Sang, 1995; 68:109 - 120
  • 5Holme S. Storage and quality assessment of platelets. Vox Sang,1998; 74(Suppl. 2) :207 - 216
  • 6Gmur J. Von-Felten A, Osterwalder B, et al. Delayed alloimmunization using random single donor platelet transfusions: a prospective study in thrombocytopenic patients with acute leukemia. Blood,1983; 62:473 - 479
  • 7Sloand EM, Yu M, Klein HG. Comparison of random-donor platelets concentrates prepared from whole blood units and platelets prepared from single-donor apheresis collections. Transfusion,1996; 36:955 - 959
  • 8李珉珉.流式细胞术检测血小板功能及其临床应用[J].中华医学检验杂志,1999,22(3):182-184. 被引量:28
  • 9金宗骧,胡开瑞.晶体盐溶液保存血小板的初步研究[J].中国输血杂志,1992,5(3):111-114. 被引量:2

共引文献2

同被引文献41

引证文献8

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部