摘要 分析了“用闪光法测定不良导体热导率实验”中脉冲尖峰产生的原因 ,并在实验装置和数据处理方面设计了减小和消除脉冲干扰的方法 . The paper analyzes the reasons of producing pulse spike in the experiment of measuring thermal conductivity of poor conductor by flash method. The experimental apparatus and data acquisition method are designed in order to reduce and eliminate the disturbance of pulse spike.
机构地区 北京大学物理系
出处 《物理实验》 北大核心 2002年第12期3-7,共5页 Physics Experimentation
关键词 测定 实验 闪光法 热导率 脉冲尖峰 屏蔽 数据拟合 脉冲干扰 flash method thermal conductivity pulse spike shield data fitting
  • 相关文献

参考文献1

二级参考文献4

  • 1Cape JA, Lehman GW. Temperature and finite pulse-time effects in the flash method for measuring thermal diffusivity. J. Appl. Phys. , 1963,34:1909~1913
  • 2Taylor RE, Clark LM. Finite pulse time effects in flash diffusivity method. High Temp High Press,1974,6:65~72
  • 3顾毓沁 施学贵.用激光脉冲技术测量金属物性误差的数值修正方法[J].稀有金属,1982,1(2).
  • 4Watt DA. Theory of thermal diffusivity by pulse technique. J. Appl. Phys. , 1966,37 : 231~240