期刊文献+

高灵敏流动注射分析检测系统的研制及应用(I)——高灵敏检测系统的研制 被引量:1

R & D and Application of Highly Sensitive Detection System for Flow Injection Analysis(I)——Development Study of Highly Sensitive Detection System
下载PDF
导出
摘要 研究设计了一个新的高灵敏流动注射分析检测系统。该检测系统主要由一个镓砷激光二极管(在780nm发射、功率5mW)光源和一个由聚四氟乙烯材料做成的细长流动池(光程100×1.4mm内径)组成。与通常10mm流动池相比,测定水中可溶性硅的灵敏度可提高10倍左右。 A new highly sensitive detection system for flow injection analysis has b een studied and designed.The new detection system is mainly composed of a GaAlA s laser diode emitting at780nm(5mW)as a light source and a thin long flo w-through cell(light path of100×1.4mm i.d.),which is made of polyt etrafluoroethylene material.Compared with normal flow-through cell of10mm,t he sensitivity for determining dissolved silica is enhanced about 10times.
作者 孙福生
出处 《苏州城建环保学院学报》 2002年第4期31-35,共5页 Journal of Suzhou Institute of Urban Construction and Environmental Protection
关键词 激光二极管 细长流动池 流动注射分析 laser diode thin long flow-through cell flow injection analysis sili con