摘要 Recovery of caprolactam from waste water of caprolactam production factory was investigated using benzene as solvent in a small-scale pulsed-sieve-plate column. First, liquid-liquid equilibrium (LLE) data were measured, including water-caprolactam-benzene system at low caprolactam concentrations, and waste water-benzene system. Then, the operating regions and mass transfer of the pulsed-sieve-plate column were measured. Finally, the overall apparent heights of a transfer unit based on continuous phase are correlated in terms of the column operation variables. Recovery of caprolactam from waste water of caprolactam production factory was investigated using benzence as solvent in a small-scale pulsed-sieve-plate column.First,liquid-liquid equilibrium (LLE) deta were measured,including water-caprolactam-benzene system at low caprolactam concentrations,and waste water-benzene system.Then,the operating regions and mass transfer of the pulsed-sieve-plate column were measured.Finally,the overall apparent heights of a transfer unit based on continuous phase are correlated in terms of the column operation variables.
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2002年第3期371-373,共3页 中国化学工程学报(英文版)
基金 Partly supported by UK's Academic Link with China Scheme (ALCS: SHA/992/307), British Council.
关键词 pulsed-sieve-plate column extraction e-caprolactam waste water 废水处理 萃取柱 己内酰胺回收
  • 相关文献

参考文献7

  • 1Lo, T. C., Baird, M. H. I., Hanson,C., Handbook of Solvent Extraction, John Wiley & Sons, New York, 343-372(1983).
  • 2Zhu, S., Luo, G., Zhang, B., "Hydrodynamics and maas transfer in a new type(FG) stack packed extraction column", Chinese J. Chem. Eng., 4 (4), 342-348 (1996).
  • 3Yu, J., Fei, W. Y., "Hydrodynamics and mass transfer in a pulsed packedcolumn", Can. J. Chem. Eng., 78 (6),1040-1045 (2000).
  • 4Ibrahim, Y. A. A., Asfour, A. F. A., Abdelmegid, M.H., et al.,"Liquid-liquid-extraction of phosphoric-acid from aqueous-solutions in pulsedcolumns", Separ. Sci. Technol.,29 (3), 415-427 (1994).
  • 5Morachevskii, A.G., Sabinin, V. E., "Liquid-liquid equilibrium datacollection", In: Chemistry Data Series, Vol.V,Part 3, Sorensen, J. M., Arlt, W.,eds., DECHEMA, 2710980).
  • 6Tettamanti, K., Nogradi, M., Sawinsky, J., "Liquid-liquid equilibrium datacollection", In: Chemistry Data Series,Vol. V, Part 3, Sorensen, J. M., Arlt, W.,eds., DECHEMA,272 (1980).
  • 7Zhejiang JuhuaGroup Company, Testimonial for Caprolactam Recovery from Waste WaterUsing Pulsed Extraction Column, Quzhou (2001). (in Chinese)

同被引文献12

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部