期刊文献+

回热系统能损分析中基准值的在线确定 被引量:7

Online Calculation of the Operating Standard Value in the Analysis of the Energy Loss of Thermodynamic System
下载PDF
导出
摘要 对回热系统主要监测参数的运行基准值进行在线计算,主要针对变工况下加热器的端差、抽汽压损的基准值定量计算,对过热器减温水量的基准值的在线计算模型进行了分析,并籍此对某电厂300MW汽轮机组进行了计算分析。回热系统运行基准值对于指导运行,在线分析及故障诊断有一定的现实意义。 This paper gives a online-calculation on the operating standard value of the main monitor parameters of thermodynamic system and lays emphasis on the difference from heater and the press loss of the extract steam pipe. The computing model of the spray desuperheating is put forward. On the base of them, a 300 MW-turbine set of a power plant is being studied and calculated. There is some significance of the standard value of the thermodynamic system for guiding operating, online analyzing and the monitoring fault.
出处 《汽轮机技术》 北大核心 2002年第6期348-350,共3页 Turbine Technology
关键词 回热系统 能损分析 基准值 变工况 汽轮机 抽气 thermodynamic system operating standard value partial load energy loss analysis
  • 相关文献

参考文献1

二级参考文献2

  • 1严俊杰.汽轮发电机组经济性诊断理论研究及应用.西安交通大学博士论文[M].,1998..
  • 2西安热工研究所.热工技术手册[M].北京:水利电力出版社,1991..

共引文献10

同被引文献36

引证文献7

二级引证文献49