摘要 对直流电晕放电等离子体烟气脱硫进行了研究,通过分析影响脱硫效率的各个因素,拟合出单因素的贡献函数.在此基础上,利用多元回归方法得出直流电晕放电等离子体烟气脱硫的效率经验公式.找出了脱硫效率与电压、水蒸气含量、氨气投加量及SO2初始浓度的函数关系.由公式得到的预测值与实验值一致性较好,因此该经验公式可为直流电晕放电等离子体烟气脱硫提供参考. SO2 removal by DC corona discharge plasma has been studied.By analyzing each influencing factor,the contributing function of each factor to SO2 removal efficiency is integrated.Basing on them,a multidimensional linear regression method has been applied to construct empirical model equation of SO2 removal efficiency.Then it finds out the function relation of SO2 removal efficiency with the influencing factors(applied voltage,vapor concentration,ammonia stoichiometry and initial SO2 concentration).The values calculated with empirical equation are very consistent with the experimental results.Therefore this equation can be referred to for the technology of SO2 removal by DC corona discharge plasma.
出处 《河北大学学报(自然科学版)》 CAS 北大核心 2007年第S1期10-13,共4页 Journal of Hebei University(Natural Science Edition)
关键词 直流电晕放电 经验公式 多元回归 影响因素 DC corona discharge empirical equation multidimensional regression influencing factor
  • 相关文献

参考文献9

  • 1吴彦,商克峰,李杰,李国锋,李锻,王宁会.电晕放电自由基注入提高烟气脱硫效率的研究[J].北京理工大学学报,2005,25(z1):193-196. 被引量:2
  • 2Miroslaw Dors,Jerzy Mizeraczyk.Influence of temperature and humidity on NO x removal by corona discharge[J].Czechoslovak Journal of Physics.1998(10)
  • 3CSHHANG J S,URAIMA K.Simultaneous removal of NOxand SO2from coal boiler flue gases by DC corona discharge ammo-nia radical shower systems:pilot plant tests[].Journal of Electrostatics.2003
  • 4CHMIELEWSKI A G,TYMINSKI B.Empirical models for NO2and SO2removal in a double stage flue gas irradiation process[].Radiation Physics and Chemistry.2000
  • 5MIROSLAW DORS,JERZY MIZERACZYK.Influence of temperature and humidity on NOxremoval by corona discharge[].Czechoslovak Journal of Physics.1998
  • 6Young Sun Mok and In-Sik Nam.Positive pulsed corona discharge process for simultaneous removal of SO2 and NOx from iron-ore sintering flue gas[].IEEE Transactions on Plasma Science.1999
  • 7Tomio Fujii.Removal of NOx by DC Corona Reactor with Water[].Journal of Electrostatics.2001
  • 8Lin H,Gao X,Luo Z Y,Cen K F,et al.Removal of NOx from wet flue gas by corona discharge[].Fuel.2004
  • 9WU Y,LI J,WANG N H,et al.Industrialexperiments on desulfurization of flue gases bypulsed corona induced plasma chemical process[].Journal of Electrocardiology.2003

二级参考文献9

  • 1[1]Li J, Wu Y, Wang N H, et al. Industrial-scale experiments of desulfuration of coal flue gas using a pulsed corona discharge plasma [J]. IEEE Trans Plasma Sci, 2003, 31(3):333 -337.
  • 2[2]Kirkpatrick M J, Finney W C, Locke B R. Chlorinated organic compound removal by gas phase pulsed streamer corona electrical discharge with reticu lated vitreous carbon electrodes [J]. Plasmas Polym, 2003, 8(3): 165-177.
  • 3[3]Hoeben W F L M, van Veldhuizen E M, Rutgers W R, et al. Degradation of aqueous phenol solutions by pulsed positive corona discharges [J]. Plasma Sources Sci,Technol, 2000,9:361-369.
  • 4[4]Chang J S, Urashima K, Tong Y X, et al. Simultaneous removal of NOx and SO2 from coal boiler flue gases by DC corona discharge ammonia radical shower systems: Pilot plant tests [J]. J Electrostatics, 2003, 57:313-323.
  • 5[5]Wu Y, Li J, Wang N H, et al. Industrial experiments on desulfurization of flue gases by pulsed corona induced plasma chemical process [J]. J Electrostatics, 2003, 57:233 -241.
  • 6[6]Lee Y H, Jung W S, Choi Y R, et al. Application of pulsed corona induced plasma chemical process to an industrial incinerator [J]. Environ Sci Technol, 2003, 37(11):2563 -2567.
  • 7[7]Ohkubo T, Kanazawa S, Nomoto Y, et al. NOx removal by a pipe with nozzle-plate electrode corona discharge system [J]. IEEE Trans, Ind, Appl, 1994, 30(4): 856-861.
  • 8[8]Lowke J J, Morrow R. Theoretical analysis of removal of oxides of sulphur and nitrogen in pulsed operation of electrostatic precitators [J]. IEEE Trans Plasma Sci, 1995,23(4): 661 -671.
  • 9[9]Li Y, Loh B C, Matsushima N, et al. Chain reaction mechanism by NOx in SO2 removal process [J]. Energy Fuels, 2002, 16(1): 155- 160.