期刊文献+

华龙一号二次侧非能动余热排出系统功能论证 被引量:11

Demonstration of Passive Residual Heat Removal System on HPR1000 Secondary Side
原文传递
导出
摘要 为提升华龙一号安全水平,响应最新法规要求,开充分吸收福岛核事故经验反馈,华龙一号设计了蒸汽发生器二次侧非能动余热排出系统(PRS),用于应对和缓解全厂断电叠加辅助给水汽动泵失效事故和给水完全丧失事故,实现事故后堆芯余热的长期有效导出。本文通过理论分析全厂断电叠加辅助给水汽动泵失效事故和给水完全丧失事故,确认了设计方案的有效性。 To improve the safety level of HPR1000,respond to latest regulatory requirements,and fully absorb the experience feedback of the Fukushima nuclear accident,passive residual heat removal system is designed for HPR1000,to mitigate SBO superimposed turbine-driven auxiliary feedwater system failure and total loss of feedwater,and to realize long term effective removal of residual heat from the reactor core after accident.This paper verified the effectiveness of the design scheme by theoretical analysis of SBO superimposed turbine-driven auxiliary feedwater system failure and total loss of feedwater.
作者 李峰 刘昌文 吴清 冷贵君 张晓华 鲜麟 赖建永 汤华鹏 Li Feng;Liu Changwen;Wu Qing;Leng Guijun;Zhang Xiaohua;Xian Lin;Lai Jianyong(Science and Technology on Reactor System Design Technology Laboratory,Nuclear Power Institute of China,Chengdu,610213,China)
出处 《核动力工程》 EI CAS CSCD 北大核心 2019年第A01期28-31,共4页 Nuclear Power Engineering
关键词 华龙一号 二次侧非能动余热排出系统(PRS) HPR1000 Passive residual heat removal system(PRS)on secondary side
  • 相关文献

同被引文献63

引证文献11

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部