摘要 管道设计中,支管连接方式的确定为管道设计重要内容。主要探讨在不能选用标准管件、需要通过焊接支管连接时,焊接支管补强形式的确定及补强面积计算。同时综合ASME、GB、SH标准对管道补强的相关规定,对焊接支管连接及补强计算中需要考虑的其他因素做了阐述。 In design of pipeline, the selection of branch and host pipe connection structure is an important content. In this article, selection of welded reinforcing structure for branch and calculation of reinforcement area were discussed for the condition where standardized fitting cannot be applied. At the same times, summarizing the relevant requirements in ASME, GB and SH standards, the factors which are needed to take into account in welded branch connection and reinforcement were expounded.
作者 李莉
出处 《化工设备与管道》 CAS 2015年第1期67-69,共3页 Process Equipment & Piping
关键词 支管连接形式 补强面积 管道分支 branch connection structure reinforcement area branch in piping