期刊文献+

现场安装方式对户用热量表流量测量特性影响的实验研究 被引量:1

Experimental Study of Installation Effect on Flow Measurement Characteristics of Household Heat Meter
下载PDF
导出
摘要 通过流量标准装置模拟3种户用热量表(机械式、U型声路超声式和W型声路超声式热量表)在7种典型的现场安装方式下的流量测量特性。结果表明:若在热量表的入口和出口处分别加4D直管段,则热量表流量测量误差满足国家检定规程的要求;机械式热量表应水平安装,超声式热量表可水平安装或竖直安装;热量表出口弯头会增大流量测量误差。 The flow measurement characteristics of three types of household heat meters (mechanical meter,Utype and Wtype ultrasonic meters)installed under different conditions were simulated to show that,addinga 4D straight pipe at heat meter’s inlet and exit can make its flow measurement error meet the requirements ofthe national verification regulations;and the mechanical heat meter should be installed horizontally togetherwith horizontal or vertical installation mode for ultrasonic heat meters,and the elbow at the heat meter exit canincrease flow measurement error.
出处 《化工自动化及仪表》 CAS 2014年第11期1260-1263,1323,共5页 Control and Instruments in Chemical Industry
关键词 热量表 流量测量 安装影响 household heat meter,flow measurement,installation effect
  • 相关文献

参考文献3

二级参考文献7

共引文献5

同被引文献7

  • 1赵颖麟,赵文.用弯管流量计取代孔板流量计节能效益分析[J].工业计量,2007,17(A01):22-23. 被引量:2
  • 2苏彦勋,梁国伟,盛健.流量计量与测试[M].2版.北京:中国计量出版社,2007:138-139.
  • 3蔡武昌 孙淮清 纪刚.流量测量方法和仪表的选用[M].北京:化学工业出版社,2003..
  • 4纪纲,纪波峰.流量测量系统远程诊断集锦[M].北京:化学工业出版社,2012.106-108;159.161.
  • 5翟秀贞,谢纪绩,杨希文,等.JJG 640-1994差压式流量计检定规程[S].北京:中国计量出版社,1994.
  • 6ISO. ISO 5167- 2-2003 Measurement of Fluid by Means of Pressure Differential Devices Inserted in Circular-corss Section Conduits Running Full-part2: Orifice Plates [S]. Geneva: International Organization for Standardization, 2003.
  • 7李明华,彭淑琴,龙竹霖,等.GB/T2624-2006用安装在圆形截面管道中的差压装置测量满管流体流量[S].北京:中国标准出版社,2006.