期刊文献+

活性炭管吸附-电感耦合等离子体质谱法测定工作场所空气中砷化氢 被引量:1

Determination of arsine in workplace air by icp-ms combined with activated carbon tube adsorption
下载PDF
导出
摘要 工作场所空气中砷化氢经活性炭管采集、以0.01 mol·L-1硝酸溶液超声洗脱后,采用电感耦合等离子体质谱法测定其含量.结果显示,砷化氢在0.1—50μg·L-1范围内呈现良好的线性关系,相关系数(r)为0.9999.砷化氢的检出限为0.04μg·L-1.加标回收率为88.2%—95.6%,相对标准偏差(n=6)值为3.8%—5.3%.该方法高效、快速、准确、灵敏,适用于工作场所空气中砷化氢的测定和安全性评价. Air samples containing Arsine were absorbed by activated carbon tube,then eluted by ultrasonic extraction under the environment of 0.01 mol·L-1 HNO3,and determined by ICP-MS.The calibration curves of Arsine showed good linearity in the range of 0.1—50μg·L-1 with the correlation coefficients(r)greater than 0.9999.The limit of detection of Arsine was 0.04μg·L-1.The average spike recovery ranged from 88.2%to 95.6%,while the relative standard deviations(n=6)were in the range of 3.8%—5.3%.This method is rapid,accurate,and has good sensitivity,which is suitable for determination of Arsine in workplace air.
作者 朱富强 卞锐 崔仲义 任鑫 李宏斌 周斌 ZHU Fuqiang;BIAN Rui;CUI Zhongyi;REN Xin;LI Hongbin;ZHOU Bin(Binzhou Center for Food and Drug Control,Binzhou,256600,China;Anhe Safety Technology Research Institute Co.,Ltd,Binzhou,256600,China)
出处 《环境化学》 CAS CSCD 北大核心 2019年第9期2159-2161,共3页 Environmental Chemistry
关键词 电感耦合等离子体质谱 工作场所 砷化氢 活性炭管 ICP-MS workplace arsine active carbon tube
  • 相关文献

参考文献2

二级参考文献13

共引文献6

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部