期刊文献+

Coupled fluid-thermal investigation on non-ablative thermal protection system with spiked body and opposing jet combined configuration 被引量:5

Coupled fluid-thermal investigation on non-ablative thermal protection system with spiked body and opposing jet combined configuration
原文传递
导出
摘要 In this paper, a Non-Ablative Thermal Protection System(NATPS) with the spiked body and the opposing jet combined configuration is proposed to reduce the aerodynamic heating of the hypersonic vehicle, and the coupled fluid-thermal numerical analysis is performed to study the thermal control performance of the NATPS. The results show that the spiked body pushes the bow shock away from the protected structure and thus reduces the shock intensity and the wall heat flux. In addition, the low temperature gas of the opposing jet separates the high temperature gas behind the shock from the nose cone of the spiked body, ensuring the non-ablative property of the spiked body. Therefore, the NATPS reduces the aerodynamic heating by the reconfiguration of the flow field, and the thermal control efficiency of the system is better than the Thermal Protection System(TPS) with the single spiked body and the single opposing jet. The influencing factors of the NATPS are analyzed. Both increasing the length of the spiked body and reducing the total temperature of the opposing jet can improve the thermal control performance of the NATPS and the nonablative property of the spiked body. However, increasing the heat conductivity coefficient of the spiked body can enhance benefit the non-ablative property of the spiked body, but has little influence on the thermal control performance of the NATPS. In this paper, a Non-Ablative Thermal Protection System(NATPS) with the spiked body and the opposing jet combined configuration is proposed to reduce the aerodynamic heating of the hypersonic vehicle, and the coupled fluid-thermal numerical analysis is performed to study the thermal control performance of the NATPS. The results show that the spiked body pushes the bow shock away from the protected structure and thus reduces the shock intensity and the wall heat flux. In addition, the low temperature gas of the opposing jet separates the high temperature gas behind the shock from the nose cone of the spiked body, ensuring the non-ablative property of the spiked body. Therefore, the NATPS reduces the aerodynamic heating by the reconfiguration of the flow field, and the thermal control efficiency of the system is better than the Thermal Protection System(TPS) with the single spiked body and the single opposing jet. The influencing factors of the NATPS are analyzed. Both increasing the length of the spiked body and reducing the total temperature of the opposing jet can improve the thermal control performance of the NATPS and the nonablative property of the spiked body. However, increasing the heat conductivity coefficient of the spiked body can enhance benefit the non-ablative property of the spiked body, but has little influence on the thermal control performance of the NATPS.
出处 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2019年第6期1390-1402,共13页 中国航空学报(英文版)
基金 supported by the Priority Academic Program Development of Jiangsu Higher Education Institutions
关键词 COUPLED method NON-ABLATIVE Opposing JET Spiked BODY THERMAL protection system Coupled method Non-ablative Opposing jet Spiked body Thermal protection system
  • 相关文献

同被引文献26

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部