期刊文献+

ASN-2880/1600轴流引风机叶片断裂原因分析及处理 被引量:7

CAUSE ANALYSIS OF BLADE BREAKAGE IN ASN-288/1600 AXIAL FLOW TYPE INDUCED DRAFT FAN AND TREATMENT THEREOF
下载PDF
导出
摘要 分析了珠江电厂国产 30 0MW机组 10 2 5t/h锅炉配置的ASN 2 880 /16 0 0型动叶可调轴流式引风机叶片断裂的原因 ,认为其主要因叶片材质不合格、铸造质量差 ,以及运行中叶片的动应力较大所致。对此 ,采取了更换叶片材质等措施 。 he causes of blade breakage in title induced draft fan with adjustable moving blades allocated for 1025t/h boiler of home-made 300MW unit at Zhujiang Power Plant in Guangzhou City have been analysed. It is considered that the main causes are as follows: (1) the quality of blade material isn't up to standard; (2) the quality of casting is bad; (3) the dynamic stress of blades in operation is larger. For these reasons, some measures, such as improving quality of the blades' material etc., have been put forward, then the problem of blade breakage has been thoroughly solved.
作者 刘义忠
机构地区 珠江电厂
出处 《热力发电》 CAS 北大核心 2003年第1期42-43,49,共3页 Thermal Power Generation