摘要 鉴于目前许多补钙制剂尚未收入国家药典,国家尚未提出测定补钙制剂中钙含量的统一方法,研究了以酸性铬蓝K为显色剂,在pH值为10.5的四硼酸钠缓冲溶液中与Ca2+络合,用分光光度法测定多种市售补钙制剂的钙含量;研究了钙-酸性铬蓝K络合物的最佳形成条件:λ=498nm,pH=10.5,显色剂用量为2mL,缓冲溶液用量为0.5mL,钙浓度在0~2.4×10-5mol/L范围内遵循朗伯-比尔定律,相对标准偏差为1.2%。 In view of the fact that calcium agents are not included in the national pharmacopoeia,the adiministration has not put forward uniform determination methods about calcium content in supplement calcium agents.This paper studies the determination of calcium content in supplement calcium agents on market.The method uses acid chrome blue K(ACBK) as coloration regent.By spectrophotometric method calcium content of five kinds of supplement agents on market are determined in the pH 10.5 of disodium tetraborate buffer.The optimum condition to form complex of calcium cation with ACBK is:λ=498 nm,pH=10.5,the amounts of coloration regent and buffer are 2 mL and 0.5 mL respectively,and the line range is 0~2.4×10-5 mol/L,RSD=1.2%.
出处 《河北科技大学学报》 CAS 2002年第4期21-24,共4页 Journal of Hebei University of Science and Technology
关键词 补钙制剂 钙含量 分光光度法 酸性铬蓝K 定量分析 含量测定 显色剂 spectrometry calcium agent calcium acid chrome blue K quality analysis
  • 相关文献

参考文献2

  • 1曹爱书 佟晶华.盐析法在羧酸及磺酸钠盐型有机试剂纯制中的应用[J].化学试剂,1982,4(2):114-114.
  • 2买光昕 申燕 王淑仁 等.双波长吸光度法同时测定钙镁[J].理化检验,1986,22(5):273-273.