期刊文献+

磁热效应直接测量用液氮冷却脉冲磁体系统

Pulsed Magnet System with Liquid Nitrogen Cooling for Direct Measurement of Magnetocaloric Effect
下载PDF
导出
摘要 介绍了一个液氮冷却脉冲磁体系统,用于磁性材料的磁热效应的直接测量。该磁体系统使用了相对小的脉冲电源(22kW),其脉冲间隔设为5档(1,2,3,4,5s)。螺线管孔径为20mm,实验测得该磁体系统能稳定工作到2.232T(在180A电流时),在螺线管中心直径为10mm的实验空间内,磁场的理论计算得到均匀度小于1%,满足了磁性材料磁热效应测试的需要。 The pulsed magnet described in this p aper operates at liquid nitrogen tem perature and is used for the direct me asurement of magnetocaloric effect of magnetic materials.It uses a relatively small pulsed power supply(22kW).With pulsed duration of 1?2?3?4and 5seconds,respectively.The solenoid has a bore diameter of 20mm.The magn et system has operated steadily to 2.232T at 180A in ex-periments.The uniformity of magnetic field is better than 1%within 10mm of solenoid center.It is satisfied f or the testing of magnetocaloric effect of magnetic materials.
机构地区 四川大学
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2003年第1期73-75,共3页 Rare Metal Materials and Engineering
基金 四川省科技厅重点科技攻关项目
关键词 测量 磁热效应 脉冲磁体系统 液氮冷却 磁性材料 magnetocaloric effect pulsed magnet system liquid nitrogen cooling
  • 相关文献

参考文献1

二级参考文献5

  • 1 Pecharsky VK, Gschneidner K A Jr. Tunable magnetic regenerator alloys with a giant magnetocaloriceffect for magnetic refrigeration from~20 to~290 K[J]. Appl Phys Lett,1997,70(23): 3299-3301.
  • 2 Pecharsky V K, Gschneidner K A Jr. Magnetocaloric effect and magneticrefrigeration [J]. Journal MMM, 1999,200: 44-56.
  • 3 Gschneidner K A Jr, et al. Active magnetic refrigerants based on Gd-Si-Gematerial and refrigeration apparatus and process[P]. US Patent:5743095 ,1998-04-28.
  • 4 Pecharsky V K, Gschneidner K A Jr. Giant magnetocaloric effect in Gd5(Si2Ge2)[J].PhysRev Lett,1997,78(23): 4494-4497.
  • 5 Pecharsky V K, Gschneidner K A Jr. The giant magnetocaloric effect in Gd5(SixGe1-x)4materials for magnetic refrigeration[A]. The Cryogenic Engineering Conferece[C].Portland:Or,1997,43:1-8.

共引文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部