期刊文献+

双通道椭圆弯晶谱仪的传递效率分析 被引量:14

Analysis of the transmission efficiency of a two-channel elliptical crystal spectrometer
下载PDF
导出
摘要 双通道椭圆弯晶谱仪(以下简称TCECS)是激光惯性约束核聚变(ICF)研究中非常重要的诊断仪器,在一个通道上用Χ光胶片或X_CCD作空间分辨测量,在另一个通道上用Χ光条纹相机作时间分辨测量,从而同时获得Χ射线的空间和时间特性。TCECS传递效率的高低将影响摄谱效果,而TCECS的传递效率取决于柱面镜的反射率、晶体的积分衍射率、滤光膜的透射率和光谱相对孔径。本文从理论上分析了TCECS传递效率的四种影响因素与波长的关系,并用Matlab6.1软件进行了数值计算,表明TCECS的传递效率随Χ射线波长增大而减小,这对今后TCECS的结构设计具有重要的指导作用。 The two_channel elliptical crystal spectrometer (TCECS) is a very important diagnostic instrument for researching inertial confinement fusion controlled by laser. Since spatial resolution is recorded by X_film or X_CCD in one channel, and time resolution is recorded by an X_streak camera in another channel, the spatial and time characteristics can be measured simultaneously. Spectrographic effects will be affected by the transmission efficiency of TCECS, which depends on the reflective ratio of a cylindrical mirror, the integrated diffraction of a crystal, the transmissivity of filter foil, and the spectrographic aperture ratio. The relations between these four influencing factors and wavelength are analyzed theoretically in this paper. The numerical calculations are done by using Matlab 6.1 software. It is indicated that transmission efficiency decreases as X_ray wavelength increases, which is very important to instruct the structural design.
出处 《光学精密工程》 EI CAS CSCD 2002年第6期592-596,共5页 Optics and Precision Engineering
基金 国家863课题资助项目(No.863_804_3)
关键词 双通道椭圆弯晶谱仪 传递效率 激光聚变 X射线诊断 ICF TCECS elliptical crystal spectrometer transmission efficiency laser fusion x_ray diagnosis
  • 相关文献

参考文献6

  • 1丁耀南.我国激光核聚变实验研究概述[J].核物理动态,1995,12(4):21-26. 被引量:6
  • 2Henke B L, Gulliksen E M,Davis J C. X-ray interaction: photoabsorption, scattering, transmission and reflection at E=50-30000eV, Z=1-92[J]. Atomic Data and Nuclear Data Tables, 1993,54(2):181-200.
  • 3Okamoto Y, Yoshikawa M, Yamaguchi N, et al. Absolute calibration of space and time-resolving flat-field vacuum ultraviolet spectrograph under both P and S polarized light conditions for plasma diagnostics [J]. Rev.Sci.Instrum. 2001,72(12): 4366-4371.
  • 4Henke B L, Yamada H T,Tanaka T J. Pulsed plasma source spectrometry in the 80-8000eV X-ray region[J].Rev.Sci.Instrum, 1983,54(10):1311-1316.
  • 5王峰,徐朝银,潘国强,赵飞云,黄志刚,范荣,王丽秋.同步辐射X射线双晶单色仪能量扫描[J].光学精密工程,2001,9(4):401-404. 被引量:9
  • 6金春水,王占山,曹健林.软X射线投影光刻原理装置的设计[J].光学精密工程,2000,8(1):66-70. 被引量:14

二级参考文献12

共引文献25

同被引文献63

引证文献14

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部