一种适用于年代测定的热释光仪 被引量:3

A type of TL reader suitable for dating
下载PDF
导出
摘要 介绍了RGD3B型热释光剂量仪的基本性能 。 This paper reported the basic performances of RGD3B TL reader that is very suitable for dating in archaeology. The matters needing attention when using this instrument and its routine maintenance were also described.
机构地区 中国防化研究院
出处 《核技术》 CAS CSCD 北大核心 2003年第1期76-77,共2页 Nuclear Techniques
关键词 年代测定 热释光 热释光剂量仪 地质年代学 Dating, Thermoluminecence, TL reader
  • 相关文献

参考文献7

  • 1[美]Mckeever S.W.S.著, 蔡干钢, 吴方, 王所亭译. 固体热释光. 北京:原子能出版社, 1993Mckeever S W S. Translated by CAI Gangang, WU Fang and WANG Suoting. Thermonuminescence of Solids. Beijing: Atomic Energy Press, 1993
  • 2李虎侯著. 热释光断代. Surrey: Scientist Press International, Inc.,1999LI Huhou. Dating with Thermoluminescence, Surrey: Scientist Press International, Inc., 1999, 80-99
  • 3赵建兴, 肖无云, 李元芳. RGD3系列热释光剂量仪的发展, 热释光应用技术研讨会, 2001ZHAO Jianxing, XIAO Wuyun, LI Yuanfang. Development of RGD3 Series of TLD Readers, Seminar on Thermoluminescence Application Techniques, 2001
  • 4Shen W X, Tang K Y, Zhu H Y, et al. New Advances in LiF:Mg,Cu,P TLD (GR-200A). 13th International Solid State Dosimetry Conference, 2001
  • 5周汝信. 热释光剂量测量的质量控制, 热释光应用技术研讨会, 2001ZHOU Ruxin. Quality Control on Thermoluminescence Dosimetry, Seminar on Thermoluminescence Application Techniques, 2001
  • 6戴军, 侯雪莉, 潘红娟. 热释光测量的质量保证和测量技术, 热释光应用技术研讨会, 2001DAI Jun, HOU Xueli, PAN Hongjuan. Quality Assurance and Measuring Technique on Thermoluminescence Dosimetry, Seminar on Thermoluminescence Application Techniques, 2001
  • 7李元方. TLD系统的特性、操作与设计, 热释光应用技术研讨会, 2001LI Yuanfang. Characteristics, Operation and Design of Thermoluminescence Dosimetry System, Seminar on Thermoluminescence Application Techniques, 2001