摘要
本文给出了电力系统暂态仿真中多π节输电线路模型的选择方法;提出了衡量输电线路模型精确度的指标。通过对不同电压等级,不同长度输电线路模型频率特性的分析,得出了根据所研究的频率范围,确定相应π节长度的和般性结论。
A method used for determining the number of equivalent sections of transmission line mod- el over the frequency range of interest,according to the model accuracy defined herein,is proposed. Factors influencing the discrepancies between continuous or distributed parameter and multiple π or lumped-parameter models are discussed. General Conclusions concerning the section lengths of line models used in transient stability, machine-network transient and switching over-voltage studies are drawn.
出处
《东南大学学报(自然科学版)》
EI
CAS
CSCD
1992年第4期83-90,共8页
Journal of Southeast University:Natural Science Edition
关键词
输电线路
电力系统
暂态仿真
transmission lines, transmission line parameters, frequency characteristic