摘要
本文介绍了立式百叶窗集灰栅的冷态模化试验效果,给出了它的优化尺寸及性能指标.还介绍了一种可用于这种复杂流场计算的数学模型.
Results of cold modelling of vertical louver dust collectors are presented together with optimized dimensions and performance specifications. A mathematic model applicable for calculating such complicated flow fields is also proposed. 8figs, 2tables and 5 refs.
出处
《动力工程》
CSCD
1992年第1期44-50,共7页
Power Engineering