摘要 随着人工心脏研究、应用的发展 ,装置的可携带性、受者的舒适性变得越来越重要 人工心脏除了装置本体的体积需要更加紧凑 ,其附属装置 ,比如电池、控制系统的体积也要减小 ,同时须保证整个系统的易用性、可靠性 为配合我所最新研制的滚动轴承和洗刷系统的叶轮血泵及永磁磁浮叶轮血泵的驱动和控制 ,使血泵能够输出符合生理要求的搏动血流量和压力 ,以及装置的微型化需要 ,笔者参考无刷电机驱动控制芯片ML4 42 8的资料 ,并根据笔者以往的控制系统研制经验 ,对人工心脏的控制系统进行了设计、优化 。 With the development and application of artificial heart, the device portability and acceptor comfortability have become more and more important. For example, the power and control system must be not only small in volume but also reliable and easy to use. According to the above requirements, and with the aid of the chip ML4428 specially used for driving control of brushless motor, we designed an optimum control system for the permanent maglev impeller blood pump, which can change its rotating speed periodically to produce physiological blood flow and pressure. The experimental results showed the sound performance of the control device.
出处 《江苏大学学报(自然科学版)》 EI CAS 2003年第1期72-74,94,共4页 Journal of Jiangsu University:Natural Science Edition
基金 国家自然科学基金资助项目 (3 9970 73 6)
关键词 研制 人工心脏 转速控制系统 反电势 锁相环 设计 优化 博动血流量 artificial heart speed control system Back EMF phase lockde loop
  • 相关文献

参考文献3

二级参考文献6

共引文献15

同被引文献6

  • 1CHEN C, YIN C K, MA Y S, et al. Design and characterization of a miniaturizen magnetically suspended centrifugal blood pump [ J ]. ASAIO 57th Annual Conference, 2011,57 (2) : 81.
  • 2CHEN C, YIN C K, MAY S. Preliminary evaluation of implantability and biocompatibility of a miniatu- rized magnetically suspended centrifugal blood pump [J ]. ASAIO 58th Annual Conference, 2012, 58 (7) : 26.
  • 3JACQUET L, VANCAENEGEM O, PASQUET A, et al. Exercise capacity in patients supported with rotary blood pumps is improved by a spontaneous increase of pump flow at constant pump speed and by a rise in native cardiac output[ J]. Artificial Organs, 2011,35 (7) : 682-771.
  • 4雷永锋,汪希平,常宇,夏翠艳,江鹏.磁悬浮人工心脏泵驱动电动机及控制研究[J].微电机,2008,41(3):72-74. 被引量:1
  • 5罗吉,高元楼.无刷直流电机在手术电锯中的应用[J].电机与控制应用,2008,35(5):54-57. 被引量:2
  • 6封志刚,曾培,茹伟民,袁海宇,李岚,钱坤喜.人工心脏输出流量和压力的神经网络估算法[J].中国生物医学工程学报,2002,21(6):568-572. 被引量:5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部