期刊文献+

The Developmentand Clinical Application of Acoustical Technique in Hip Joint

The Developmentand Clinical Application of Acoustical Technique in Hip Joint
下载PDF
导出
摘要 A non- invasive acoustical system was developed for the measurement of transmission properties of acoustic waves in the hip joints.The instrumentation consisted of three sub- system s. An excitation system employed a vibratory force at the sacrum of the test subjects.A transduction system included a pair of identical microphones installed in the tubes of two stethoscopes,which were placed at the greater trochanters on both sides for picking up the acoustical signals transm it- ted across the hip joints.The data acquisition and analysis system was a portable signal analyzer with a program of dual channel digital filter for m easuring the power of acoustical signal in 1/ 3- oc- tave frequency bands.2 7normal adults,2 0 normal pre- school children and 4 0 norm al neonates were random ly selected for testing.Coherence function (CF) and discrepancy(D) was measured during the testing.Results from the three groups showed that there was a high coherence of the signals (CF>0 .9) and a sm all discrepancy(D<3d B) between bilateral hips in the frequency range of2 0 0— 315 Hz.For normal neonates,there was a wider frequency range of16 0 - 315 Hz in which the acoustical signals m aintained a high coherence (CF>0 .93) and a smaller discrepancy (D <2 d B) was observed.This study showed that the development of the acoustical technique pro- vided a practical m ethod with objective parameters.The results obtained in this study can offer a baseline for further investigation of hip disorders particularly those related to structural abnorm ali- ties of the hip. A non- invasive acoustical system was developed for the measurement of transmission properties of acoustic waves in the hip joints.The instrumentation consisted of three sub- system s. An excitation system employed a vibratory force at the sacrum of the test subjects.A transduction system included a pair of identical microphones installed in the tubes of two stethoscopes,which were placed at the greater trochanters on both sides for picking up the acoustical signals transm it- ted across the hip joints.The data acquisition and analysis system was a portable signal analyzer with a program of dual channel digital filter for m easuring the power of acoustical signal in 1/ 3- oc- tave frequency bands.2 7normal adults,2 0 normal pre- school children and 4 0 norm al neonates were random ly selected for testing.Coherence function (CF) and discrepancy(D) was measured during the testing.Results from the three groups showed that there was a high coherence of the signals (CF>0 .9) and a sm all discrepancy(D<3d B) between bilateral hips in the frequency range of2 0 0— 315 Hz.For normal neonates,there was a wider frequency range of16 0 - 315 Hz in which the acoustical signals m aintained a high coherence (CF>0 .93) and a smaller discrepancy (D <2 d B) was observed.This study showed that the development of the acoustical technique pro- vided a practical m ethod with objective parameters.The results obtained in this study can offer a baseline for further investigation of hip disorders particularly those related to structural abnorm ali- ties of the hip.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2002年第4期362-366,共5页 华中科技大学学报(医学英德文版)
关键词 hip joint acoustical technique digital filter hip joint acoustical technique digital filter
  • 相关文献

参考文献8

  • 1Kernohan W G,Beverland D E,McCoy G F et al.The diagnostic potential of vibration arthrography[].Clinical Orthopaedics and Related Research.1986
  • 2Saha S,Lakes R S.The effect of soft tissue on wave propagation and vibration tests for determining the in vivo properties of bone[].Journal of Biomechanics.1977
  • 3Siffert R S,Kaufman J J.Acoustic assessment of fracture healing.Capabilities and limitations of "a lost art "[].American Journal of Orthopedics.1996
  • 4Peylan A.Direct auscultation of the joint[].Rheumatism.1953
  • 5File P,Wood J P,Kreplick L W.Diagnosis of hip fracture by the auscultatory percussion technique[].American Journal of Emergency Medicine.1998
  • 6Stone M H,Richardson J B,Bennet G C.Another clinical test for congenital dislocation of the hip[].The Lancet.1987
  • 7Richardson J B,Foo C K,Stone M H et al.Attenuation of sound transmission in congenital dislocation of the hip[].Journal of Bone and Joint Surgery British Volume.1987
  • 8Mollan R A B,McCullagh G C,Wilson A.Critical appraisal of auscultation of human joints[].Clinical Orthopaedics and Related Research.1982

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部