摘要
针对青山热电厂 9、1 0号锅炉运行不稳定而多次非计划停运的实际情况 ,通过现场检查和试验 ,从燃烧原理出发 ,分析了造成锅炉燃烧不稳定的原因 。
In the light of unplanned out of service of boiler due to unsteady combustion and based on the principle of combustion, the cause of unsteady combustion was analyzed, and through on site inspection and test, the modification measure was suggested.
出处
《湖北电力》
2003年第1期20-22,共3页
Hubei Electric Power