摘要
通过实例,对YT型调速器限制开度运行和限负荷运行时机组过速进行了分析、处理并提出了改进措施.
This paper studies an application of YT governor, and gives an analysis when it is running under limited or load limited condition, which may lead to the result of unit overspeed. Improved methods are also introduced to handle the problem.
出处
《南昌水专学报》
2002年第4期53-56,共4页
Journal of Nanchang College of Water Conservancy and Hydroelectric Power
关键词
调速器
运行方式
过速
处理
水电站
水轮机
governor
operating conditions
over speed
disposal
improved method