摘要
介绍了重庆地区某U型垂直换热器地源热泵实验系统在夏季的供冷情况 ,提出了对地源热泵系统运行的改进方案 。
presents the measurement done to the ground-source heat pump system for testing with U-shaped vertical heat exchangers in cooling mode in Chongqing,gives some suggestions for improvement, and establishes a heat transfer model.
出处
《建筑热能通风空调》
2003年第1期1-4,共4页
Building Energy & Environment
关键词
供冷
测试
传热模型
夏季
地源热泵
U型垂直换热器