期刊文献+

程控反渗透系统的工艺设备配置设计要点 被引量:2

Design Characteristics of Equipment Disposal of Program-Controled Reverse Osmosis System
下载PDF
导出
摘要 简述了应用于地表水的程控反渗透系统的工艺水泵、澄清过滤设备、加药装置以及RO装置的一些配置设计要点。 In this paper, the design characteristics of equipment disposal of program-controled reverse osmosis system were introduced briefly, which were related to process pump, clarifier and media filter , reagent dosing and RO unit.
出处 《净水技术》 CAS 2003年第1期25-27,共3页 Water Purification Technology
关键词 设计 反渗透 程序控制 配置 地表水 澄清 过滤 加药装置 reverse osmosis program-control equipment disposal
  • 相关文献

参考文献7

  • 1[1]J. A.Redondon Lomax I. Experiences with the pretreatment of raw water with high fouling potential for reverse osmosis plant using FILMTEC membranes Desalination, 1997,1l0:167~182.
  • 2郅玉声.反渗透工艺系统[J].净水技术,2002,21(1):7-10. 被引量:6
  • 3[3]Abdul G hani I. Dalvi,et al. Role of chemical constituents in recycle brine on performance of scale control additives in MSF plants,Desalination,2000, 129:173~186
  • 4[4]R.Sheikholesami,Fouling mitigation in membrane Processes,Desalination,1999,123:45~23
  • 5[5]US Dow Chemical Co.Ltd,FILMTEC membranes system design,1995,4:2
  • 6[6]Saehan company CSM RO system design,2000,5~8
  • 7郅玉声.反渗透系统设计问题的探讨[J].净水技术,2001,20(3):22-25. 被引量:7

二级参考文献4

  • 1美国Hydranadtics公司.分离膜技术应用论文集[M].,1998,9.8.
  • 2[1]美国HYDRANADTICS 公司. RO SYSTEM DESIGN, 1998, 4:P3-1
  • 3[3]美国DOW CHEMICAL 公司. FILMTEC MEMBRANES SYSTEM DESIGN, 1995, 4: 2
  • 4[4]SAEHAN COMPANY. CSM RO SYSTEM DESIGN, 2000, 5-8

共引文献10