用气体发生-MIPAES法测定了溶液中的S^(2-)和SO_(3)^(2-).样品中S^(2-)和SO_(3)^(2-)同稀H_2SO_4作用,产生H_2S和SO_2,用Ar气将产生的气体带入MIP.在216.9nm处测定硫的发射强度,考察了各实验参数对测定S^(2-)和SO_(3)^(2-)的影响.S^(2-)和SO_3^(2-)的检出限分别为0.08μg和0.25μg.RSD小于5%.
In this paper,the determination of S2-and SO32-in solution were investigated by gas generation MIPAES.In the reaction cell S2-and SO32-reacted chemically with H2SO4 and formed H2S and SO2,respectively.The H2S and SO2 generated were carried into the MIP and the emission intensity at 216.9 nm was recorded.Various experimental conditions for determining S2-and SO32-were studied.The detection limits for S2-and SO32-are 0.08μg and 0.25μg.respectively.Good precision(RSD<5%)were observed either for S2-or for SO32-
出处
《高等学校化学学报》
SCIE
EI
CAS
CSCD
北大核心
1992年第11期1364-1367,共4页
Chemical Journal of Chinese Universities
基金
国家自然科学基金
关键词
硫化物
亚硫酸盐
MIPAES
Microwave induced plasma atomic emission spectrometry,Sulfide,Sulfite