摘要
在国际上首次提出并证明了一个重要结论:“冲击测量系统总的冲击测量误差近似等于各部件冲击测量误差之和”,论证了线性冲击测量系统总的指数波响应时间和方波响应时间分别等于各部件的指数波响应时间和方波响应时间之和,从而纠正了以往的错误计算公式。
An important conclusion that the total impulse measurement error of the whole impulse measuring system equals approximate the sum of the impulse measurement errors of its indiuidul parts is presented and proved first time in the world. It is proved that the total exponential wave response time and the total step response time of the whole linear impulse measuring system equals the sum of the exponential wave response times and the step response times of its individual parts respectively, and it corrects the former wrong calculation formula.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
1992年第3期8-12,共5页
High Voltage Engineering
关键词
冲击测量
误差
指数波
响应时间
impulse measuring system impulse measurement error exponential wave response time step response time