摘要
通过对国产10kV/630A/20kA真空断路器实际电寿命试验以及大电流开断试验,研究了大功率纵磁场真空断路器采用大电流加速电寿命试验方法的可行性,试验及理论分析表明,对于纵磁场真空断路器采用大电流加速电寿命试验不仅方法可行,而且还能由短路电流分断次数推算出等效额定电流下的操作次数来。
The possibility of life test of axial magnetic type vacuum switches by high current acceleration has been investigated. The test result and the theoretical analysis show that not only this test method is utilizable but also an equivalent switch life at rated current can be calculated fromnumber of short-circuit current breaking.
出处
《高压电器》
CAS
CSCD
北大核心
1992年第6期40-44,共5页
High Voltage Apparatus
基金
国家自然科学青年基金
关键词
真空断路器
电寿命试验
大电流
vacuum circuit breaker, e lectric life test, research,magnetic field, high current