光纤连接损耗的物理机理及其补偿技术的讨论 被引量:2

The Discussion of Physical Mechanism of Fiber Loss and Compensation Technology
下载PDF
导出
摘要 从理论上分析了光纤连接损耗的起因和物理机理;分析并讨论了目前几种新型损耗补偿技术:提高光纤材料的纯净度、使用更好的光纤器件、采用精良的制造工艺;综述了补偿光纤损耗技术的新器件、新工艺、新材料。 This essay is based on the analysis of the origin and the physical mechanism of the fiber transmission loss,link loss and plugin loss.It discusses several kinds of means of surveying the fiber loss:the direct comparation method,the cutoff method,the plugin method.It gives two kinds of new compensation technology of the fiber loss:to exploit new type of fiber material,to find out the more rational and new type of fiber structure.It provides the guiding theory for practical work.
作者 宋立新
出处 《孝感学院学报》 2002年第6期20-23,共4页 JOURNAL OF XIAOGAN UNIVERSITY
基金 湖北省教育厅自然科学研究重点项目(2001A27008)。
关键词 光纤连接损耗 物理机理 损耗补偿 结构参数失配 光纤通信系统 纯净度 fiber loss physical mechanism loss compensation
  • 相关文献

参考文献6

  • 1[美]马库塞.光纤测量原理[M].北京:人民邮电出版社,1986.
  • 2刘国须等.光纤测试[M].北京:人民邮电出版社,1986.
  • 3Kazuo S.Beam expand fiber using thermal diffusion of the dopant[J].Lightwave Technology.,1990,8(8):1151-1160.
  • 4Zhang W,Wong S,Hulten O,et al.Erbium-doped-fiber splicing with a real-time control technoque in technical digest of OFC/IOOC'93[J].San Jose(Op-tical Society of America ),1993,(4).
  • 5刘雪峰,孙军强,王宏锷,黄德修,李再光.小芯径掺铒光纤与单模光纤低损耗接续的研究[J].光学学报,1994,14(8):854-857. 被引量:2
  • 6Agrawal G P.Fiber-Optics Communication Systems[M].John Wiley&sons,Inc,1992.

二级参考文献1

  • 1Zheng W,1993年

共引文献1

同被引文献24

  • 1邓立新,冯莹,唐波.光纤免疫生物传感器的探针设计[J].传感技术学报,2004,17(3):520-525. 被引量:12
  • 2杨玉孝,王永峰,熊开利,刘斌,谭玉山,谭洪,陈端军.光纤生物免疫传感器原理及关键技术研究[J].光子学报,2005,34(1):121-125. 被引量:10
  • 3欧阳红兵.超声波孔加工技术进展[J].机械制造,1997,35(5):7-9. 被引量:4
  • 4GOLDEN J P,RABBANY S Y, ANDERSON G P. Ray tracing determination of evanescent wave penetration depth in tapered fiber optic probes[C]. SPIE, 1992,1796 : 9-13.
  • 5ANDERSON G P,GOLDEN J P,LIGLER F S. An evanescent wave biosensor-part I : Fluorescent signal acquisition from step-etched fiber optic probes[J]. IEEE Trans Biomed Eng, 1994,41 (6) : 578-584.
  • 6GOLDEN J P, ANDERSON G P, RABBANY S Y. An evanescent wave biosensor-Part II : Fluorescent signal acquisition from step-etched fiber optic probes[J]. IEEE Trans Biomed Eng ,1994, 41(6) :585-591.
  • 7GAO H H, CHEN Zhong ping, KUMAR J, et al. Tapered fiber tips for fiber optic biosensors[J]. Opt Eng, 1995, 12 (34):3465-3469.
  • 8GLASS T R,LACKIE S, HIRSCHFELD T. Effect of numeric aperture on signal level in cylindrical waveguide evanescent fluorsensors[J]. Appl Opt, 1987,26(11) :2181-2187.
  • 9MARCUSE D. Launching light into fiber cores from sources in the cladding[J]. J Lightwave Tech , 1988,6(8) : 1273-1279.
  • 10NIDHL N,SNEH A. Evanescent wave fiber optic fluorosensor : Effect of tapering configuration on the signal acquisition[J]. Opt Eng, 1998,1 (37) :220-228.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部