期刊文献+

Biomechanical evaluation of atlantoaxial transarticular screw fixation technique 被引量:1

Biomechanical evaluation of atlantoaxial transarticular screw fixation technique
原文传递
导出
摘要 Objective: To compare the biomechanical differences among the atlantoaxial transarticular screw fixation (Magerl) and other posterior fixation techniques. Methods: Seven preserved atlantoaxial complex specimens were harvested and fixated with Magerl, Magerl plus Gallie wiring, Magerl plus Brooks wiring, pure Brooks, pure Gallie, and Halifax interlaminar clamping fixation, respectively. The torque for every fixation technique was measured at the point of five degree rotation of the atlantoaxial joint. Results: The torque for Magerl was 6.59 N·m± 1.14 N·m , which was significantly higher than any other pure posterior techniques including Gallie ( 1.74 N·m± 0.31 N·m ). Brooks ( 4.06 N·m± 0.48 N·m) and Halifax ( 3.44 N·m± 0.87 N·m) (P< 0.01 ), but less than Magerl plus brooks ( 9.94 N·m± 1.45 N·m) (P< 0.01 ). No statistically significant difference was found between Magerl and Magerl plus Gallie wiring ( 7.61 N·m± 1.10 N·m) or between Brooks and Halifax. Conclusions: Compared with other pure posterior fixation techniques the atlantoaxial transarticular screw fixation technique provides more torsion resistance capacity. It is also suggested that combined Gallie wiring do not add any biomechanical superiority to this technique.
出处 《Chinese Journal of Traumatology》 CAS 2000年第2期89-92,共4页 中华创伤杂志(英文版)
关键词 BIOMECHANICS Internal fixators Atlantoxia joint 寰枢关节损伤 内固定 生物力学
  • 相关文献

参考文献5

  • 1Marcotte P,Dickman CA,Sonntag VKH,et al.Posterior atlantoaxial facet screw fixation[].Journal of Neurosurgery.1993
  • 2Stillerman CB,Wlson JA.Atlantoaxial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases[].Neurosurgery.1993
  • 3Grob D,Crisco III J,Panjabi MM,et al.Biomechanical evaluation of four different posterior atlantoaxial fixation techniques[].SPINE.1992
  • 4Madawi AA,Casey ATH,Solanki GA,et al.Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique[].Journal of Neurosurgery.1997
  • 5Handson PB,Montesano PX,Sharkey NA,et al.Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability[].SPINE.1991

同被引文献17

  • 1黄令坚,郑文忠.钳夹式多爪棘突固定器的研制[J].骨与关节损伤杂志,1996,11(6):374-374. 被引量:9
  • 2Derek P,Lindsey MS, Kyle E,et al. The effects of an interspinous implant on the kinematics of the instrumented and adjacent level in the lumbar spine[J]. Spine,2003,28(19):2192~2197.
  • 3Leahy JC, Mathias KJ,Heaton A, et al. Design of spinous process hooks for flexible fixation of the lumbar spine[J]. Proc Inst Mech Eng,2000,214(5):479~487.
  • 4Shepherd DE, Leahy JC,Hukins DW, et al. Slippage of a spinous process hook during flexion in a flexible fixation system for the lumbar spine[J]. Med Eng Phys,2001,23(2):135~141.
  • 5Coe JD,Warden KE,Herzig MA,et al. Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws,laminar hooks, and spinous process wires[J]. Spine,1990,15:902~907.
  • 6Graft H. Lumbar instability surgical treatment without fusion:Soft system stabilization[J]. Rachis,1992,4:123~137.
  • 7Duncan ET, Shepherd PhD,Johanna C, et al. Spinous process strength[J]. Spine,2000,25(3):319~323.
  • 8Grob D, Criso J,Panjabi MM,et al.Biomechanical evalution of four different posterior atlanto-axial fixation technique[J]. Spine,1991,17:480~490.
  • 9Hajek PD, Lipka J,Hartline P, et al. Biomechanical study of C1~C2 posteror arthrodesis technique[J]. Spine,1993,18:173~177.
  • 10Richter M, Schmidt R,Claes L,et al. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques[J]. Spine,2002,27(16):1724~1732.

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部