摘要
用内电解法对某制药废水进行预处理研究。通过曝气和投加一定量的氧化剂可以增强内电解处理效果,结果表明,在Fe/C比为1:1, pH值为3.0,H2O2(30%)投加量为500mg/L,反应时间为3小时的情况下,该法对CODCr去除率可达70%,色度去除率为90%,并大为提高废水的可生化性,可以生化处理。
The pretreatment of internal electrolysis to a certain pharmaceution wastewater was investigated ,and the effect of internal electrolysis was enhanced by aeration and adding oxidant.The result showed that removal rates of CODCr could reach more than 70%, removalrate of color was 90% if the weight proportion of iron and charcoal was 1:1, pH 3.0, react time 3 hours and the dosage of oxidant 500mg/L, and then the wastewater could become degradable for biochemical treatment.
出处
《武汉科技学院学报》
2003年第1期39-42,共4页
Journal of Wuhan Institute of Science and Technology