锅炉烟管管端泄漏原因分析

INVESTIGATION OF FRAQUENCY LEAKING ACCIDENT AT THE BOILER′S ENDS OF THE FIRE TUBES
下载PDF
导出
摘要 DZW 6 1.5 7型锅炉使用三年后其烟管管端多次出现泄漏。对泄漏烟管的化学成分、显微组织和硬度 ,以及锅炉水质进行了检验 ,结果均属正常。通过分析 ,认为烟管管端泄漏是局部温差应力造成的。进水温度低且进水位置不当 ,破坏了水循环 ;省煤器阻塞 ,烟灰烟垢严重 ,使烟气温度升高 ,造成管端产生温差应力 ,导致锅炉烟管管端频发泄漏事故。 Frequency leaking accidents of fire tubes ends happened after a DZW6 1.57 type of boiler had been used for three years, and the leaking locations are the same. To find the cause of these accidents, we conduct the chemical composition analysis, microstructure and hardness examination of the fire tubes. All of results show that they are all right. After further investigation, we discovered: Owe to the low temperature and unsuitable location of inlet water, the water circulation was broken. The economizer was blocked up and flue ash was accumulated too much as well as the scale, so that the temperature of flue gas rose. Both of these two factors lead to the result of temperature difference stress at the tube ends. Finally, we get the conclusion that frequency leaking accidents of fire tubes ends were caused by the local temperature difference stress.
出处 《理化检验(物理分册)》 CAS 2003年第2期106-107,112,共3页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 烟管 原因分析 锅炉 管端 泄漏 水质检验 显微组织 硬度 Boiler Tube end Leaking Analysis
  • 相关文献

参考文献2

  • 1GB1576-2001.工业锅炉水质[S].[S].,..
  • 2GB/T699-1999,优质碳素结构钢[S].

共引文献54

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部