高烈度区某超限复杂高层建筑结构设计与研究 被引量:3

Structural design and study on a super high-rise complex building in high intensity areas
原文传递
导出
摘要 目前在我国在抗震设防烈度8度及以上地区已建的高度超过200m的超高层复杂结构并不多见。宁夏万豪大厦位于银川市,银川市地处8度抗震设防区,地震分组为第二组。万豪大厦主体结构是由五星级酒店和四星级酒店垂直叠加而成的一栋50层的复杂超高层建筑,主体高度216m,目前为宁夏自治区标志性建筑。本工程结构存在超高、大底盘、平面和竖向不规则、高位斜柱转换等多项抗震不利因素,属于超限复杂高层建筑结构。结构设计采用多种计算模型和计算程序对其进行反复分析和研究,并采取有针对性的抗震性能化设计及抗震措施。 At present,there are a few super high-rise complex buildings higher than 200m in the seismic fortification intensity 8 degrees and above areas in our country.Marriott building is located in Yinchuan,and Yinchuan is located in 8degree seismic fortification areas for the second earthquake group.The main structure is a 50-story super high-rise complex building vertically congruences by five-star hotel and four-star hotel,the hight of main body is 216m.At present,Marriott building is the landmark buildings in Ningxia autonomous region.The seismic unfavorable factors of this structure is super high-rise building,big chassis,horizontal and vertical irregular,high conversion inclined columns switching,so this structure is a overrun complex high-rise building structure.Many kinds of calculation models and programs were carried out for the structural design,and targeted measures for seismic performance-based design were adopted.
出处 《建筑结构》 CSCD 北大核心 2012年第S1期59-67,共9页 Building Structure
关键词 超限高层建筑 混合结构 高烈度区 斜柱转换 矩形钢管柱 基于性能的抗震分析 high-rise buildings hybrid structure high intensity area oblique column switching rectangular steel tube column performance-based seismic analysis
  • 相关文献

参考文献1

  • 1CECS 159-2004.矩形钢管混凝土结构技术规程[S],2004.

共引文献5

同被引文献8

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部