钢筋混凝土剪力墙连梁钢筋间距不足,连梁承载能力相对于其刚度严重失衡是当前两大设计通病。以解决剪力墙连梁钢筋间距不足问题为基础,对提高连梁抗剪能力和延性进行探索,提出解决方案。
The space between steel bar in some coupling beams of shear wall is not enough. And some time,the bearing capacity with coupling beams is mismatching to its angular rigidity. These are common faults on designing of shear walls and coupling beams nowadays. Base of solving coupling beams lack of space betweensteel bar,solutions were put forward to made its bearing capacity powerful and its ductility better.
出处
《建筑结构》
CSCD
北大核心
2016年第S2期180-182,共3页
Building Structure
关键词
剪力墙连梁
钢筋间距
承载能力
刚度
对角斜向钢筋
shear walls coupling beams
the space between steel bar
bearing capacity
angular rigidity
steel bar on the cross