摘要 本文通过实验室水静压力试验系统模拟水密耐压电缆在水下的真实受压情况,主要研究3 MPa水静压力对300 m长水密耐压电缆体积变化的影响。结果表明:在3 MPa水静压力试验后电缆外观未发生明显变形,电缆与金属材料受力器连接处未发生开裂,电缆经水静压力试验后通电性能满足使用要求;水密耐压电缆的体积收缩变化率可以用压力传导液的液位变化率进行表征,电缆在3 MPa水压下保压1 h体积收缩变化率为6.4%。 This paper mainly studied the influence of watertight cable volume changing under 3 MPa water pressure by the laboratory water pressure test system. Result shows that cable shows no obvious deformation after pressure test, the connector between cable and metal material is unopened; The electrical signal can be transformed normally by the cable after the water pressure test; The volume change rate of watertight cable can be characterized by the variation of water level, the volume change rate of the watertight cable under 3 MPa water pressure is 6.4%.
出处 《舰船科学技术》 北大核心 2016年第S1期90-92,共3页 Ship Science and Technology
基金 海洋公益性行业科研专项经费资助项目(201105031-3)
关键词 水静压力 水密耐压电缆 体积变化 补压 water pressure watertight cable volume change pressure compensation
  • 相关文献

参考文献4

二级参考文献17

  • 1饭泉信吾,张卓亚.橡胶/金属硫化粘合体在腐蚀环境中的粘合耐久性[J].橡胶参考资料,1993,23(4):21-29. 被引量:1
  • 2伍华东.橡胶与金属骨架粘合失效原因分析及解决方法探讨[J].中国橡胶,2006,22(20):32-35. 被引量:2
  • 3IEC 60092-350:2001 Part 350: Shipboard PowerCables-general Construction and Test Requirements[S].
  • 4MIL-DTL-24643C:2009 Detail Specification Cables, Electric, Low Smoke Halogen-free, for Shipboard Use General Specification for[S].
  • 5GJB774-1989.舰船用电缆和软线通用规范[S].
  • 6IEC 60332-3-22:2000 Part 3-22: Test for Vertical Flame Spread of Vertically-mounted Bunched Wires or Cables - Category A.
  • 7GJB1916-1994.舰船用低烟电缆和软线通用规范[S].[S].,..
  • 8CB/Z221-1998.舰艇电缆选择规则[S].[S].,..
  • 9GBJ1916-1994.舰船用低烟电缆和软线通用规范[S].[S].,..
  • 10IEC60092-350:2001.船用电力电缆:一般结构及试验要求[S].[S].,..

共引文献10

同被引文献18

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部