期刊文献+

Microwave based detector for continuous assessment of intracerebral hemorrhage 被引量:2

Microwave based detector for continuous assessment of intracerebral hemorrhage
原文传递
导出
摘要 Continuous detecting of the rate and size of hematoma expansion is crucial for intracerebral hemorrhage management and treatment. To continuously assess intracerebral hemorrhage in human head, a novel nondestructive microwave head detecting system is presented in this study. An open-ended cylindrical waveguide is employed as sensing antenna, which is operated associated with a coaxial cable for signal transmission and data acquisition. Measurement of amplitude data over the frequency range of 100–400 MHz is processed to evaluate the changes in intracerebral hemorrhage, based on the system's operating principle that the sensor functions as a resonant cavity. Furthermore, 3D printed anatomically and dielectrically realistic human head phantoms with different lesions are fabricated to verify the efficacy of this proposed hemorrhagic stroke assessment system.It is worth noting that the quantitative results show that the system operating in TE_(111) mode is able to detect intracerebral hemorrhage size change as small as 1 cm^3, demonstrating the possibility of this proposed head evaluating system in future preclinical trials. Continuous detecting of the rate and size of hematoma expansion is crucial for intracerebral hemorrhage management and treatment. To continuously assess intracerebral hemorrhage in human head, a novel nondestructive microwave head detecting system is presented in this study. An open-ended cylindrical waveguide is employed as sensing antenna, which is operated associated with a coaxial cable for signal transmission and data acquisition. Measurement of amplitude data over the frequency range of 100–400 MHz is processed to evaluate the changes in intracerebral hemorrhage, based on the system's operating principle that the sensor functions as a resonant cavity. Furthermore, 3D printed anatomically and dielectrically realistic human head phantoms with different lesions are fabricated to verify the efficacy of this proposed hemorrhagic stroke assessment system.It is worth noting that the quantitative results show that the system operating in TE_(111) mode is able to detect intracerebral hemorrhage size change as small as 1 cm^3, demonstrating the possibility of this proposed head evaluating system in future preclinical trials.
出处 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2019年第3期365-372,共8页 中国科学(技术科学英文版)
基金 supported by the Scientific and Technological Research Program of Chongqing Municipal Education Commission(Grant No.KJ1704102) the Doctoral Foundation of Chongqing University of Posts and Telecommunications(Grant No.A2016-77)
关键词 MICROWAVE EVALUATION INTRACEREBRAL HEMORRHAGE microwave evaluation intracerebral hemorrhage
  • 相关文献

同被引文献11

引证文献2

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部