摘要
针对华能丹东电厂1号炉水氢导超标,通过离子色谱分析、离子摩尔电导率核算,找出了磷酸根、硫酸根等杂质含量高是1号炉水氢导超标的原因,对炉水采用氢氧化钠处理的方法,取得了良好的效果。
According to the over-standard phenomenon of NO. 1 boiler water hydrogen conductivity,the reason is found out that the concentration of impurity is high such as phosphate radical and sulfate radical by ion chromatographic analysis and ion molar conductivity calculation. Using the method of sodium hydroxide treatment in boiler water achieves good results.
出处
《东北电力技术》
2015年第12期16-19,共4页
Northeast Electric Power Technology
关键词
炉水
氢导
氢氧化钠
色谱仪
含盐量
摩尔电导率
Boiler water
Hydrogen conductivity
Sodium hydroxide
Chromatograph
Salt content
Molar conductivity