本文结合工程实际,对某热电联产工程综合水泵房在地基不均匀沉降产生后,如何因地制宜地进行针对性加固设计进行了现状调查、原因分析和方案比选,工程实施效果达到了设计要求,取得了良好的社会效益,推广应用价值高.
This paper combining practical engineering carried out the investigation, reason analysis, and scheme comparison about how to improve the current situation of general water pump house which foundation has the problem of non-uniform settlement in a heat and power cogeneration project,the work got super expectation of implementing effect and good economical and societal results.