期刊文献+

Vestibular-evoked myogenic potentials recorded from miniature pigs and rats 被引量:2

Vestibular-evoked myogenic potentials recorded from miniature pigs and rats
下载PDF
导出
摘要 Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from the neck extensor muscle or masseter muscle in normal adult Bama miniature pigs and rats anesthetized with 3%pentobarbital sodium and Sumianxin Ⅱ.Results:At 80 dB SPL,the first positive wave(P wave) of VEMPs was recognizable in 58%of rats with a latency of 6.45±0.23 ms and an amplitude of 1.45±0.49 μV when recorded from the neck extensor muscle,and in 50%of rats with a latency of 6.38±0.34 ms and an amplitude of 1.57±0.35 μV when recorded from the masseter muscle.In miniature pigs,at the same stimulus intensity,P wave was recognizable in 58%of the animals with a latency of 7.65±0.64 ms and an amplitude of 1.66±0.34 μV when recorded from the neck extensor muscle,and in 50%of the animals with a latency of 7.65±0.64 ms and an amplitude of 0.31±0.28 μV when recorded from the masseter muscle.Conclusion:VEMP can be induced from both neck extensor and masseter muscles in the miniature pig and rat.For a given species,the site of recording affects P wave induction rate and amplitude but not latency.Consistency and repeatability analysis suggests that the masseter muscle is a better recording site in miniature pigs while the cervical extensor is a better recording site in rats.For a given recording site,both latency and amplitude of the P wave are slightly greater in miniature pigs than in rats. Objective:To report vestibular evoked myogenic potentials from different recording sites(neck extensor or masseter muscles) in miniature pigs and rats.Methods:Potentials were recorded using 1000 Hz tone bursts from the neck extensor muscle or masseter muscle in normal adult Bama miniature pigs and rats anesthetized with 3%pentobarbital sodium and Sumianxin Ⅱ.Results:At 80 dB SPL,the first positive wave(P wave) of VEMPs was recognizable in 58%of rats with a latency of 6.45±0.23 ms and an amplitude of 1.45±0.49 μV when recorded from the neck extensor muscle,and in 50%of rats with a latency of 6.38±0.34 ms and an amplitude of 1.57±0.35 μV when recorded from the masseter muscle.In miniature pigs,at the same stimulus intensity,P wave was recognizable in 58%of the animals with a latency of 7.65±0.64 ms and an amplitude of 1.66±0.34 μV when recorded from the neck extensor muscle,and in 50%of the animals with a latency of 7.65±0.64 ms and an amplitude of 0.31±0.28 μV when recorded from the masseter muscle.Conclusion:VEMP can be induced from both neck extensor and masseter muscles in the miniature pig and rat.For a given species,the site of recording affects P wave induction rate and amplitude but not latency.Consistency and repeatability analysis suggests that the masseter muscle is a better recording site in miniature pigs while the cervical extensor is a better recording site in rats.For a given recording site,both latency and amplitude of the P wave are slightly greater in miniature pigs than in rats.
出处 《Journal of Otology》 CSCD 2016年第3期138-143,共6页 中华耳科学杂志(英文版)
基金 supported by grants from the National Basic Research Program of China (973 Program)(#2012CB967900) National Natural Science Foundation of China (31300624,81470684) Postdoctoral Science Foundation of China (2015M571818) Six Major Categories of Talent (2014-WSN043,2011-WS-074) Innovation and Entrepreneurship Training Program for College Students in Jiangsu Province(201510313003Z,201510313003,KYLX14-1455) Clinic Medical Special Foundation of Jiangsu Province (b12014032)
关键词 Vestibular evoked myogenic potentials Miniature pigs RATS Masseter muscle Cervical extensor muscle Vestibular evoked myogenic potentials Miniature pigs Rats Masseter muscle Cervical extensor muscle
  • 相关文献

同被引文献6

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部