期刊文献+

机械式有载分接开关灭弧方案的研究 被引量:2

Arc Extinguishing Scheme Research on Mechanical On-Load Tap-Changer
下载PDF
导出
摘要 有载分接开关是变压器在调压过程中的重要器件。介绍了传统的机械式有载分接开关及混合式有载分接开关的灭弧方案,总结了有载分接开关的改进过程,给出了三种改进方案,并进行了对比。指出全电力电子式有载分接开关将是未来的发展方向。 The on-load tap-changer is the important part for transformer in pressure regulating process. Introduction was made to the arc ex-tinguishing scheme of traditional mechanical and mixed on-load tap-changer, the improved process of the on-load tap-changer was summarized and three kinds of improved schemes were given and compared. It is pointed out that the full electric power electronic type on-load tap-changer will be the trend of development.
作者 沈艳涛 于群
出处 《电工电气》 2015年第8期23-26,共4页 Electrotechnics Electric
关键词 变压器 有载分接开关 机械式 混合式 灭弧 transformer on-load tap-changer mechanical mixed arc extinguishing
  • 相关文献

参考文献3

  • 1张德明编著.变压器分接开关选型与使用[M]. 中国电力出版社, 2006
  • 2Harlow, J. H.,Stich, F. A.An Arcless Approach to Step-Voltage Regulation. Power Engineering Review, IEEE . 1982
  • 3Quinton,G.L.ADVANTAGES OF AN ARCLESS VOLTAGE REGULATOR. IEEE Transactions on Industry Applications . 1984

同被引文献24

引证文献2

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部