摘要
以α ,β ,γ ,δ 四 (5 磺基噻吩 )卟啉为柱前衍生试剂 ,用含 1 5mmol/LH3BO3-NaOH缓冲溶液 (pH9 0 )和 5 0× 10 - 3mol/L溴代三丁基胺 (TBA Br)的乙氰 -水 (3 0 :70 ,V/V)溶液作流动相 ,检测波长 43 0nm ,在KromasilC1 8柱上 ,同时分离测定了铜、镉和钴三种金属络合物 ,检出限 (S/N =3 )分别为 0 2 0 ,0 16,和 0 13ng/mL。方法用于水样分析 ,结果与光度法相符。
In this paper α,β,γ,δ-tetrakis(5-sulfothienyl) porphyrin is used as the precolumn derivative agent and the simultaneous determination of copper,cadmium and cobalt has been achieved in 13 min at 430nm on kromasil C 18 column with acetonitrile-water(30:70,V/V),contaning 1.5mmol/L H 3BO 3-NaOH(pH9.0) and 5.0×10 -3 mol/L TBA.Br as the mobile phase.The detection limits are 0.20,0.16 and 0.13ng/mL for copper,cadmium and cobalt respectively,when the ratio of signal to noise is 3.This method is sensitive and has been applied to the analysis of natural water sample.
出处
《冶金分析》
CAS
CSCD
北大核心
2003年第1期34-36,共3页
Metallurgical Analysis
关键词
分离
测定
反相液相色谱法
铜
镉
钴
卟啉
TSTP
显色剂
reversed phase high performace liquid chromatography
copper
cadmium
cobalt
α,β,γ,δ-tetrakis(5-sulfothienyl) porphyrin