期刊文献+

实时电阻抗断层成像系统对离体心脏充盈模型成像的初步结果 被引量:3

Prelinimary image results of in vitro heart perfusion model by real-time electrical impedance tomography
下载PDF
导出
摘要 目的 :探讨电阻抗断层成像技术 (EIT)在心血管系统成像中的潜在应用价值 ,同时通过对离体动物器官的成像实验改进已有的成像实验系统。方法 :用自行设计的实时电阻抗断层成像系统 ,对离体动物心脏充盈模型进行EIT的实验。结果 :EIT图像对离体心脏充盈模型中各腔室的电阻抗分布的变化敏感。结论 AIM: To investigate the possibility of the electrical impedance tomography(EIT) used in cardiovascular imaging, and assessing and improving the imaging system. METHODS: Heart perfusion model in vitro was used to be imaged by the real time EIT developed by us. RESULTS: EIT images exhibited sensitivity to variation of resistivity distribution of the heart perfusion model. CONCLUSION: EIT imaging technique can be widely needed in cardiovascular diagnosis.
出处 《心脏杂志》 CAS 2003年第1期12-14,共3页 Chinese Heart Journal
关键词 实时电阻抗断层成像系统 离体心脏充盈模型 心血管系统成像 electrical impedance tomography cardiovascular imaging
  • 相关文献

参考文献2

二级参考文献13

  • 1汤梦星.动态电阻抗断层成像算法的研究:硕士毕业论文[M].西安:第四军医大学,1997..
  • 2汤梦星,硕士学位论文,1997年
  • 3Woo E J,Med Biol Eng Comput,1994年,32卷,4期,530页
  • 4Zhu Q S,IEEE 0-78030785-2,1992年,1704页
  • 5Hua Ping,IEEE Trans Med Imaging,1991年,10卷,4期,621页
  • 6McCulloughCH,RobbRA.Ultrafastcomputedtomography;principlesandinstrumentation[A].In:SkortonDJ,SchelbertHR,WolfGL,BrundageBH,ed.Marcus'sCardiacImaging[M].2ndedition.Philadelphia:Saunders,1996.
  • 7臧益民.心血管研究进展[M].北京:世界图书出版公司,1993.
  • 8KammKF.Thefutureofdigitalimaging[J].BrJRadio,1997,70:145.
  • 9PettigrewRI.Magneticresonanceincardiovascularimaging[A].In:ZaretBL,ed.FrontiersinCardiovascularImaging[M].NewYork:RavenPess,1993:113~135
  • 10ReesMR.Activatedguidwiretechniquefortreatingchroniccoronaryarteryocclusion[J].Lancet,1995,346:953.

共引文献17

同被引文献11

  • 1尤富生,董秀珍,史学涛,付峰,刘锐岗,秦明新,汤孟兴,李江.电阻抗断层成像硬件系统的初步研究[J].中国体视学与图像分析,2003,8(2):114-118. 被引量:8
  • 2付峰,秦明新.电阻抗断层图像重构算法[J].国外医学(生物医学工程分册),1995,18(5):255-262. 被引量:12
  • 3盛剑霓.工程电磁场数值分析[M].西安:西安交通大学出版社,1990..
  • 4Povill R, Pere R. Quantification in multifrequency tomography[J]. Physiol Meas, 1995,16 (Suppl 3A) :A69-A78.
  • 5Frerichs I, Hahn G, Schrder T, et al. Electrical impedance tomography in monitoring experimental lung injury [J]. Intensive Care Med, 1998,24:829-836.
  • 6Smith RWM.Design of a real-time impedance imaging system for medical applications [ C ]. Doctorial dissertation of University of Sheffield. UK. 1990.
  • 7Denyer CWL.Electronics for real-time and three - dimensional electrical impedance .tomographys [ C ]. Doctorial dissertation of Oxfrod Brookes, UK ,1996.
  • 8Povill R,Riu P.Quantification in multifrequency tomography[J].Physiol Meas,1995,16 (3 Suppl A):A69-78.
  • 9Cheng KS,Isaacson D,Newell JC,et al.Electrode models for electric current computed tomography[J].IEEE Tran Biomed Eng,1993,BME-36:918-923.
  • 10王化祥,王超,陈磊.EIT系统复合电极结构性能分析及优化设计[J].仪器仪表学报,2002,23(2):189-191. 被引量:7

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部